星城web Oxygen Clean Electronic Valves
![]() |
星城web's Oxygen Clean Series electronic valves are available in 2-way or 3-way, normally-closed or fully-ported.听 They are designed for use with oxygen applications and will work with air and inert gas. The "O-E" Series pneumatic valves utilize a unique patented valve system that has been used and proven throughout many industries. With a low power consumption of only 0.67 watts, a response time of 5 to 10 milliseconds, and voltages of 6, 12, or 24 volt DC, these new valves offer unlimited flexibility in design. |
The valves are ultrasonically cleaned, assembled, inspected and tested in an enclosed controlled area with a state-of-the-art positive pressure High Efficiency Particulate Air (HEPA) filtration system.
For complete details on the "O-E" series of electronic valves that provide safety of operation in oxygen applications with quick response, low power consumption and long life, request additional information below.
鈥⑻ 听Valves are ultrasonically cleaned, assembled, inspected and tested in an enclosed controlled area with a state-of-the-art positive pressure HEPA filtration system
鈥 Both organic and inorganic contaminants such as particulate matter and Hydrocarbon oils are removed
鈥 No organic sealants, adhesives or lubricants are used in the manufacturing process
鈥 Component parts are lubricated with Oxygen-compatible PFPE (perfluoropolyether) grease, only as needed for assembly
鈥 Individual testing and inspection is accomplished 听听 听utilizing compressed Nitrogen and ultra-violet light
Cleaning For Oxygen Service Specification ES-3.41
The purpose of this document is to describe the materials and methods 星城web Instrument Laboratory, Inc. uses to clean EV, ET, and EC valves intended for use in oxygen-enriched environments.
General
鈥 All parts are cleaned, assembled and tested in an enclosed room (鈥淐ontrolled Area鈥) that is kept under positive pressure with HEPA filtered air.
鈥 Access to Controlled Area is restricted to trained 星城web personnel.
鈥 Gloves are used to handle all cleaned parts.
鈥 No organic sealants, adhesives or lubricants are used in the manufacture or assembly of these products.
鈥 All assembly tools and test equipment are designed and cleaned to avoid contamination of product.
Cleaning
鈥 All parts are cleaned to normal production standards before being brought into the Controlled Area.
鈥 Parts are ultrasonically cleaned in a hot, dilute solution of oxygen-compatible cleaner in purified water
for at least 10 minutes.
鈥 Parts are rinsed in purified water, then dried with heat and/or forced (ambient) air or compressed nitrogen.
Post-Cleaning Inspection
鈥 Cleaned parts are inspected under white and ultraviolet light to insure the absence of particulate and hydrocarbon contamination.
鈥 After inspection, parts are either assembled immediately, or bagged and labeled as 鈥淐leaned for Oxygen service鈥 for later assembly.
Lubrication
鈥 Components are lubricated with oxygen compatible PFPE grease, only as needed for assembly.
Assembly/Testing
鈥 All assembly tools and test equipment are designed and cleaned to avoid contamination of product.
鈥 Assembled valves are tested using compressed nitrogen.
Packaging & Identification
鈥 Finished valves are double bagged in heat sealed polyethylene bags and labeled 鈥淐leaned for Oxygen Service.鈥
Usage
鈥 Valves should remain in their sealed bags until ready for assembly.
鈥 Care must be taken to avoid contaminating parts during assembly.
鈥 Any lubricants or thread sealants used with this valve must be compatible with oxygen.
鈥 Purchaser is responsible for safely applying these valves in an oxygen environment.
鈥 星城web reserves the right to change this specification without notice.
鈥 Purchaser assumes complete and total responsibility and liability for any and all penalties, remedies
View Oxygen Clean Valves Brochure
View 星城web Oxygen Clean Valves
View 星城web Oxygen Clean Manifolds