Two Hand, No Tie-Down (THNTD) Safety Circuit

Category: 

颁濒颈辫辫补谤诲鈥檚 hand safety circuit module is a self-contained modular circuit board with all interconnections required to provide a Two-Hand, No-Tie-Down (THNTD) pneumatic circuit. Use of the will assure simple and rapid installation of your Two-Hand-No-Tie-Down circuit.

The main function of this control is to require a machine operator to use both hands to actuate the equipment, helping to insure that the operator鈥檚 hands are not in a position to be injured by the machine as it is in motion.


听 (PDF)
听 (PDF)



THNTD Safety Circuit

Maintained Output
Maintained Output

Occurs as long as both palm buttons are held. Release of either button terminates the output (shipped in this configuration)

How: Connect E to F using a piece of 5/32鈥 O.D. tubing as a jumper


Momentary Output
Momentary Output

Gives a single output pulse that is about 50 ms in duration.

How: Plug E with 5/32鈥 Push-Quick Plug (11755 screw plug if using CM-023); F is open


Cancelable Output
Cancelable Output

Terminates the output after a Normally-Open 3-way limit valve has been tripped, even if both palm buttons are held.

How: Interpose Normally-Open 3-way valve or other circuit function


Cancel Output After Time Delay
Cancel Output After Time Delay

A variation of Cancelable Output (above) where pneumatic delay valve such as 颁濒颈辫辫补谤诲鈥檚 Model is set to cancel the output after a designated time interval has elapsed regardless of how long the buttons are held.